Building Specifications

  • Square Footage: 335,613 SF / 300’W x 838’L

  • Configuration: Cross Dock

  • Floors: Lapidolith concrete hardener sealer and dust proofer shall be placed on the entire slab on grade. 10 mil vapor barrier has been included in slab throughout slab on grade

  • Column Spacing: 55’6”d x 48’w with 60’ speed bays

  • Loading Doors: 120 (9’ x 10’) non-insulated, 24 gauge roll formed steel sections (nominal) doors. Each door shall have pairs of Z-Guard Door Protectors and Dock Bumpers. Dock finishes to the tenant’s requirement.  4 drive-in doors (12’ x 14’) insulated, 24 gauge roll formed steal sections (nominal) doors with 4 concrete ramps

  • Truck Court Depth: 180’ total depth, 60’ concrete apron and 70’ heavy duty asphalt, 50’ trailer parking area

  • Parking: Parking for 195 autos in front; 151 trailers

  • Lights: Eighteen (18) – six (6) lamp T-8, 2’ x 4’ fixtures for vacant shell building lighting

  • Electrical: The building shall have one (1) 1,600 amp service.

  • Ceiling Height: 36’ minimum at 1st bay bar joist

  • Sprinkler Type: 100% via an ESFR system with K25 sprinkler heads

  • Roofing System: A mechanically attached 0.045 white reinforced TPO membrane, and 0.045 TPO standard wall flashing with (1) layer 4” THK (R-23.6) of isocyanurate roof insulation. Manufacturer’s fifteen-year labor and material warranty included.

  • HVAC: Twenty (20) gas fired unit heaters with gas piping, flue piping and thermostats. Eight (8) 2,500 CFM centrifugal exhaust fans with mechanical louvers roof mounted exhaust fans. Eight (8) 3’-0” x 6’-0” intake louvers with motoroperated dampers.